Very happy with qbl always quick shipping and quality products. Will continue to shop through qbl
VIND Silenced Subfloor Fan Kit 200 mm | Fan + 1 m Acoustic Ducting
Pickup available at Quick Bloom Lights Store, Sydney Australia
Usually ready in 1 hour
* Shipping Information & Discreet Packaging
Free Shipping
Free shipping applies to any item over $35 AUD.
Express Shipping
Upgrade to Express Shipping for $12.95, which moves your order to the front of the queue and ships the same business day if placed before noon. Premium carriers are used for express orders.
Delivery Times
Metro areas: 1–2 business days
Perth: 5–7 business days
Regional / remote areas: 5–10 business days
Shipping times may vary based on carrier delays or regional factors.
PO Boxes & Parcel Lockers
Select Australia Post at checkout for an additional $20 — this is required for PO Box delivery, as our other carriers don't deliver to PO Boxes. Not all items are eligible due to size or weight; email sales@quickbloomlights.com.au before ordering to confirm.
Bulky or Remote Orders
In some cases, if an item is too large, heavy, or the delivery address is remote or rural, an additional shipping charge may apply. If this occurs, our team will contact you before dispatch to confirm any extra cost or available delivery options.
Discreet Packaging
All orders are packed plain and unbranded. We remove or cover any manufacturer logos, product names, or giveaways to ensure your privacy.
Authority to Leave (ATL)
All parcels are shipped with Authority to Leave (ATL) unless otherwise specified by the customer. This allows faster delivery and avoids missed deliveries, but please ensure your drop-off location is secure.
Return policy and Warranty
2 Year Warranty on AC Infinity Products (PH/EC Probes excluded)
1 Year on Seed Starter and other standard products, unless otherwise specified
For full warranty and claim details, see our Warranty Information page. For returns, see our Refund Policy.
A VIND 200 mm silenced EC fan and 1 metre of 200 mm acoustic ducting in one order. The fan handles the motor noise inside its own insulated housing; the ducting handles what is left travelling down the duct behind it. Together they are the two halves of a quiet install, and the metre of acoustic duct goes exactly where it does the most good — straight off the fan outlet.
The fan and the acoustic ducting bought on their own come to $379.90; the kit is $349.95, and it arrives as one order with the right two things in it.
What is in the kit
VIND 200 mm Silenced Inline Fan — EC motor on vibration-damping springs inside a 40–50 mm acoustic chamber. 995 m³/h, 656 Pa, 47 dB, 90 W. Manual PWM speed controller and 3 m power cord included.
VIND 200 mm Acoustic Ducting, 1 m — perforated aluminium inner core inside a 26 mm wall of high-density glass wool, rated by the manufacturer at up to 50% noise reduction.
Why the ducting matters as much as the fan
People buy a quiet fan and are surprised the install is still audible. The reason is that a fan makes noise in two places, and only one of them is the motor. The other is air moving at speed down a thin foil duct, which passes sound along the run and radiates it wherever the duct happens to be.
Treating the motor without treating the duct fixes half the problem. That is why this pairing exists: the fan housing absorbs the motor, the first metre of acoustic duct absorbs the airflow, and the combination is what people actually mean when they say a subfloor fan is quiet.
Where it goes
Subfloors and crawl spaces under suspended timber floors, where damp air sits and never moves. Roof spaces and attics that bake through summer. Garages, sheds and enclosed cavities. Anywhere the air needs shifting and the fan will be running long hours within earshot of somebody.
The 200 mm size suits a larger subfloor, a long duct run, or a run that has to bend its way around piers and services before it reaches an outside wall. Length and bends both cost airflow, so a difficult run wants the bigger fan even where floor area alone would not say so.
Specifications
| VIND Silenced Subfloor Fan Kit 200 mm | |
|---|---|
| Kit code | VINDSFK200 |
| Duct size | 200 mm (8″) |
| Max airflow | 995 m³/h (276 L/s, 586 CFM) |
| Max static pressure | 656 Pa |
| Noise level | 47 dB (fan, full speed) |
| Motor | EC with PWM speed control, spring-suspended |
| Power consumption | 90 W, 1.4 A |
| Voltage | 100–240 V, 50/60 Hz |
| Fan dimensions | 689 mm long, Ø290 mm housing, 7.3 kg |
| Ducting | 1 m, 26 mm glass wool wall, up to 50% noise reduction (manufacturer) |
| In the box | Fan, manual PWM speed controller, 3 m power cord, 1 m acoustic ducting |
| Not included | Hangers, ratchet straps, duct clamps, temperature and humidity controller |
| Warranty | 2 years, Australia-wide |
FAQ
Is the kit cheaper than buying the parts separately?
Yes. The fan is $329.95 and the metre of acoustic ducting is $49.95 — $379.90 bought on their own. The kit is $349.95, so you save $29.95 and get one line on the order with the right two things in it, rather than working out which duct suits which fan.
Is one metre of ducting enough?
For the noise, usually yes — the first metre off the fan is where the treatment counts most. For the run, almost certainly not: you will need standard ducting to get from the fan to wherever the air is going. Think of the acoustic metre as the quiet section at the noisy end, not the whole duct.
200 mm or 150 mm?
200 mm for a larger subfloor, a long run, or a duct that has to weave around piers and services. The 150 mm fan handles a smaller footprint with a short, direct run and takes up far less space. Send us the dimensions and how the duct has to travel if you are close to the line — an oversized fan turned down is quieter than a small one flat out.
Will it fit where I want to put it?
Check first. The fan alone is 689 mm long, Ø290 mm across and 7.3 kg — considerably bigger than a bare 200 mm fan, because the acoustic chamber is the whole point. Measure the cavity, make sure the mounting will take the weight, and leave room for the duct to leave the fan without an immediate hard bend.
Do I need an electrician?
Not for the fan itself — it comes with a 3 m power cord and a standard plug. If you want it hard-wired, on a dedicated circuit, or fed from a point that does not exist yet, that part is an electrician's job.
Can it run continuously?
Yes, and that is the intent. EC motors are built for long runtimes, and 90 W for this much airflow makes round-the-clock ventilation reasonable rather than expensive.